Androstenedione QANDR

Method(s) Chromatography/Mass Spectrometry
Specimen Required
Collect

One 5 mL plain red (no gel) top tube. Also acceptable: Plasma collected in: lavender (EDTA), royal blue (EDTA), dark green (sodium heparin) or light green (lithium heparin) top tube.

Transport

1 mL serum refrigerated (Min: 0.25 mL)

* Collection Instructions *

  • Separate serum after clotting.
  • Do not submit glass tubes.
  • Any early morning specimen is preferred.
Stability

Ambient: 72 hours

Refrigerated: 28 days

Frozen: 2 years

Unacceptable Conditions
  • Gross hemolysis
  • Samples collected in serum separator tubes (SST)
  • Glass tubes
Schedule Sun-Fri
CPTCode 82157
Notes Performing Laboratory-Quest Diagnostics Nichols Institute-San Juan Capistrano, CA